Check Valves

Non-return valves that stop reverse flow. Swing check and ball check designs in 316 stainless, Duplex 2205, WCB cast steel and coated cast iron.

We're currently adding products.

View all Valves →

About Check Valves

A check valve only lets flow go one way. It has no handle and nothing to operate: the line itself opens it and reverse flow closes it. That makes it the cheapest insurance on a pump discharge, because the thing it prevents (a full column of water running back through a stopped pump) wrecks impellers, spins pumps backwards and bursts joints. Our range covers both of the designs that matter in water and wastewater work, the swing check and the ball check, in bodies from coated cast iron up to Duplex 2205.

Key Features

  • ✓Swing check valves, hinged disc, lowest pressure drop
  • ✓Ball check valves, no hinge or pin to jam on solids
  • ✓316 stainless (CF8M) for water and wastewater
  • ✓Duplex 2205 for seawater and high-chloride service
  • ✓WCB cast steel to 0-50 bar for high-pressure duty
  • ✓Resilient seated options to soften water hammer
  • ✓Table D/E and ANSI 150lb/300lb flanging

Swing Check vs Ball Check Valves

Swing Check Valves

Use a hinged disc that swings open with forward flow and closes under reverse flow or gravity. Best for horizontal lines or where low pressure drop is important.

  • • Lower pressure drop than ball check
  • • Suitable for larger pipe sizes
  • • Resilient seated for bubble-tight seal

Ball Check Valves

Use a ball that lifts off the seat under forward flow and drops back to seal on reverse flow. Simple design with no moving parts to wear.

  • • Simple, reliable operation
  • • Works in any orientation
  • • Good for slurry and wastewater

Looking for Duckbill Check Valves?

For stormwater outfalls and drainage applications, see our zero-maintenance rubber duckbill valves.

View Duckbill Check Valves →

Swing check or ball check: how to choose

A swing check valve has a hinged disc that the flow pushes open and gravity or reverse flow swings shut. It gives you the lowest pressure drop of any check valve, so it's the usual choice on larger-bore water lines where head loss matters, but it wants to be installed horizontally (or vertically with upward flow) so the disc can seat properly.

A ball check valve uses a free ball that lifts off its seat under forward flow and rolls back into it when flow stops. There's no hinge, no pin and no linkage, which is why it copes with wastewater and light slurry that would eventually jam a disc. It also works in orientations a swing check won't tolerate.

The short version: if the line is clean water and you're counting head loss, use a swing check. If the line carries solids, or the geometry is awkward, use a ball check. If you're not sure which your duty is, tell us what's in the water and we'll say which way to go.

Water hammer, and why the closing speed matters

When a pump stops, flow reverses before the check valve shuts. The longer the valve takes to close, the faster that reverse flow is moving when it finally slams the disc onto the seat, and that sudden stop is what you hear as a bang through the pipework. It isn't just noise: repeated water hammer loosens joints, cracks fittings and shortens the life of everything downstream of it.

A resilient seated swing check softens the seating impact, which is why our resilient seated Table D and Table E units are the common specification on pump discharge. On a long rising main, or anywhere the bang is already a known problem, the valve choice is only part of the answer and the pipework design matters too. Tell us the application at quote stage rather than matching the flange and hoping.

Materials, and the two that are worth knowing about

316 stainless (CF8M) is the standard for water, wastewater and anything corrosive, and it's where most enquiries land. Coated cast iron with an EPDM seat is the economy option for general water service. WCB cast steel is the high-pressure body: our WCB swing check in ANSI 300lb carries a 0 to 50 bar pressure range in DN50 to DN100, with a Stellite seat facing, which puts it well above anything in the stainless range.

Duplex 2205 is the one worth knowing about if you're working with seawater, brine or high-chloride water. It's a duplex stainless with roughly twice the strength of 316 and considerably better resistance to chloride pitting and stress corrosion cracking, which is exactly the failure mode that kills 316 in warm saline service. We stock it as a ball check in DN50 to DN300. It costs more than 316 and on ordinary water duty you don't need it, but on the duties where 316 fails early it's the correct answer rather than an upgrade.

Check Valves Specifications

DesignsSwing check (hinged disc) and ball check (free ball)
Body materials316 stainless (CF8M), Duplex 2205, WCB cast steel, FBE coated cast iron
Flange standardsAS2129 Table D and Table E, ANSI 150lb and ANSI 300lb
Ball check, 316 stainless316ss/CF8M, 0 to 16 bar, flanged Table E
Ball check, Duplex 2205DN50 to DN300, for seawater and high-chloride duty
Swing check, WCB ANSI 300lbDN50 to DN100, WCB/Stellite, 0 to 50 bar
Seat materialsEPDM, PTFE and metal seated options

Figures shown against a named product belong to that product. Tell us your line size, pressure and operating temperature and we will confirm what suits the duty.

Who selects these valves

Kris McKeown, Director, Dewater Products. Over 12 years as a Mechanical Engineering Technician and more than 17 years in industrial sales. Kris sources and specifies the valve range directly with the manufacturers.

Dewater Products has supplied industrial fluid piping products Australia-wide from Perth since 2015, sourcing from over 20 approved manufacturers across 5 countries. If you are not sure which valve suits your duty, call 1300 271 290 and talk it through before you order.

Check Valves FAQs

What's the difference between a swing check valve and a ball check valve?

A swing check uses a hinged disc and gives the lowest pressure drop, so it suits clean water on larger bores, but it needs correct orientation for the disc to seat. A ball check uses a free ball with no hinge or pin, so it handles wastewater and light slurry that would eventually jam a disc, and it tolerates orientations a swing check won't.

Which check valve do I need for high pressure?

Our WCB cast steel swing check flanged to ANSI 300lb carries a 0 to 50 bar pressure range in DN50 to DN100, with a Stellite seat facing. That's the high-pressure option in the range. The 316 stainless ball check is rated 0 to 16 bar, so for anything above that the WCB body is the one to specify.

Will a check valve stop water hammer?

It affects it. When a pump stops, flow reverses before the valve shuts, and the faster that reverse flow is moving at the moment of closure, the harder the bang. A resilient seated swing check softens the seating impact, which is why it's the common specification on pump discharge. If water hammer is already a known problem on the line, the pipework design matters as well as the valve, so tell us the application rather than just the flange size.

When is Duplex 2205 worth the extra cost over 316 stainless?

In seawater, brine and high-chloride water. Duplex 2205 has roughly twice the strength of 316 and much better resistance to chloride pitting and stress corrosion cracking, which is the failure mode that kills 316 in warm saline service. On ordinary water duty you don't need it. We supply it as a ball check in DN50 to DN300.

Can a check valve be installed vertically?

A ball check will generally work in any orientation. A swing check needs the disc to be able to seat under gravity or reverse flow, so it belongs in horizontal pipe or in vertical pipe with upward flow. Fitting a swing check into vertical downward flow stops it sealing. Confirm the orientation with us when you order and we'll match the design to it.

Need Help Selecting the Right Valve?

Call 1300 271 290 or request a quote.